| Quantity: | |
|---|---|
LS-80
KDSI Also can do OEM
Product Description ______________________________________________________________
| Product Name | Hot Sales LS-80 DC4-20mA 40MPa Wide Angle Analog Panel DC Ampere Pressure Meter | ||
| Type | Panel meter | Service | OEM ODM |
| Composition | Acrylic resin cover | Model | LS-80 |
| ABS Resin frame and case | |||
| PC glass fiber base mounting fitting included | |||
| Scale Plate | Normally Aluminum Alloy or Customized | Front Frame(mm) | 80*80 |
| Features | Zero Adjustment/Aging Test/Anti-static | Panel cutout (mm) | DIA.71mm |
| Operating Position | Normally in vertical position or customized | Color | Customized |
| Pointer | Normally Aluminum Alloy or Customized | Accuracy | Class 1.5 |
| Overshoot | Less than 15% when the pointer is at the 2/3 of the scale.(Can be customized) | Service Condition | -20~+50 degree |


Product Description ______________________________________________________________
| Product Name | Hot Sales LS-80 DC4-20mA 40MPa Wide Angle Analog Panel DC Ampere Pressure Meter | ||
| Type | Panel meter | Service | OEM ODM |
| Composition | Acrylic resin cover | Model | LS-80 |
| ABS Resin frame and case | |||
| PC glass fiber base mounting fitting included | |||
| Scale Plate | Normally Aluminum Alloy or Customized | Front Frame(mm) | 80*80 |
| Features | Zero Adjustment/Aging Test/Anti-static | Panel cutout (mm) | DIA.71mm |
| Operating Position | Normally in vertical position or customized | Color | Customized |
| Pointer | Normally Aluminum Alloy or Customized | Accuracy | Class 1.5 |
| Overshoot | Less than 15% when the pointer is at the 2/3 of the scale.(Can be customized) | Service Condition | -20~+50 degree |


| No. | Test Item | Allowed value | Actual value | Conclusion |
| 1 | Appearanceinspection | Visual control | Meet the demand | |
| 2 | Insulation resistance | ≥5MΩ | Meet the demand | |
| 3 | Voltage test | Voltage 2KV | Meet the demand | |
| 4 | Response time | 4s | 1.5s | Meet the demand |
| 5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
| 6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
| 7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
| 8 | Test of overshoot | ±20 | 0 | Meet the demand |
| 9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
| 10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
| 11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
| 12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
| 13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
| 14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
| 15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
| 16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
| 17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
| 18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
| 19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
| 20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |
| No. | Test Item | Allowed value | Actual value | Conclusion |
| 1 | Appearanceinspection | Visual control | Meet the demand | |
| 2 | Insulation resistance | ≥5MΩ | Meet the demand | |
| 3 | Voltage test | Voltage 2KV | Meet the demand | |
| 4 | Response time | 4s | 1.5s | Meet the demand |
| 5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
| 6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
| 7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
| 8 | Test of overshoot | ±20 | 0 | Meet the demand |
| 9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
| 10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
| 11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
| 12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
| 13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
| 14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
| 15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
| 16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
| 17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
| 18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
| 19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
| 20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |