KDSI Also can do OEM
| Model | Size | Range | Accuracy | Weight | Packing |
| T9160P | DIA160mm*TH37mm | -30~50℃ (-20~120℉) | 2C,+/-5F | 0.09KG | White box security package |
| Product Function: The product is used for measuring ambient temperature, making you able to keep abreast of the ambient temperature, so that you can take appropriate measures to adapt to or change your environment temperature, thus ensuring your living environment comfortable and dry. Product Feature: Plastic housing, plastic lens, large dial display design, easy to read remotely The product has a slingshot clamp position on its back, and generally used for craftwork inlaying. It can also be used alone by mounting it on the wall. | |||||


| No. | Test Item | Allowed value | Actual value | Conclusion |
| 1 | Appearanceinspection | Visual control | Meet the demand | |
| 2 | Insulation resistance | ≥5MΩ | Meet the demand | |
| 3 | Voltage test | Voltage 2KV | Meet the demand | |
| 4 | Response time | 4s | 1.5s | Meet the demand |
| 5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
| 6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
| 7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
| 8 | Test of overshoot | ±20 | 0 | Meet the demand |
| 9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
| 10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
| 11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
| 12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
| 13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
| 14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
| 15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
| 16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
| 17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
| 18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
| 19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
| 20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |