Availability: | |
---|---|
Quantity: | |
BE-48DA
KDSI Also can do OEM
Specification | ||
Model | BE-48 DA | |
Measure range | Current(I) 0-30A | |
Expand function | RS485,Modbus,switch input/output,analog output | |
Frame size | 48*48mm | |
Cutout size | 45*45mm | |
Material | ABS plastic shell housing | |
Power supply | AC/DC 80~270V,AC380V, AC100V |
Product Description | |
Overview BE-DA series High precision measurement DC current. Provide the digital tube display, local data query. Digital LED display ,can set the ratio of current. | |
Features 1.Communication interface 1 way RS-485 communication, Modbus-RTU protocol 2.Baud rate: 1200~9600bps, the default 2400bps 3.Switch input support 2 stem node input. 4.The switch output support 2 relay output, capacity: AC 250V/5A, DC 30V/5A 5.Transmission output support 1 analog output: 0/4~20mA or 0~5/10V 6.Impedance: <20mΩ |
Technical parameters | Value | |
input | Normal value | Current :1A、5A,(Or ordered by customer) |
Overload | continual 1.2times,instaneous 10times/5s; | |
Power consumption | <0.4VA(per phase) | |
Frequency | 45~65Hz | |
Accuracy class | 0.5 | |
Display | LED display,range in:0~9999 | |
Power supply | Voltage range | AC/DC 80V-270V, AC 220V, AC380V, AC100V, DC48V, DC24V |
Power consumption | <4VA | |
Insulation resistance | >100MΩ | |
Isolation voltage | Between power supply/input/output 2kV/1min(rms) | |
MTBF | ≥50000h | |
Environment | Temperature | Work:-10~55℃,Storage:-25~+70℃ |
Humidity | ≤93%RH,In the place without dew and corrosive gas | |
Altitude | ≤2500m |
Specification | ||
Model | BE-48 DA | |
Measure range | Current(I) 0-30A | |
Expand function | RS485,Modbus,switch input/output,analog output | |
Frame size | 48*48mm | |
Cutout size | 45*45mm | |
Material | ABS plastic shell housing | |
Power supply | AC/DC 80~270V,AC380V, AC100V |
Product Description | |
Overview BE-DA series High precision measurement DC current. Provide the digital tube display, local data query. Digital LED display ,can set the ratio of current. | |
Features 1.Communication interface 1 way RS-485 communication, Modbus-RTU protocol 2.Baud rate: 1200~9600bps, the default 2400bps 3.Switch input support 2 stem node input. 4.The switch output support 2 relay output, capacity: AC 250V/5A, DC 30V/5A 5.Transmission output support 1 analog output: 0/4~20mA or 0~5/10V 6.Impedance: <20mΩ |
Technical parameters | Value | |
input | Normal value | Current :1A、5A,(Or ordered by customer) |
Overload | continual 1.2times,instaneous 10times/5s; | |
Power consumption | <0.4VA(per phase) | |
Frequency | 45~65Hz | |
Accuracy class | 0.5 | |
Display | LED display,range in:0~9999 | |
Power supply | Voltage range | AC/DC 80V-270V, AC 220V, AC380V, AC100V, DC48V, DC24V |
Power consumption | <4VA | |
Insulation resistance | >100MΩ | |
Isolation voltage | Between power supply/input/output 2kV/1min(rms) | |
MTBF | ≥50000h | |
Environment | Temperature | Work:-10~55℃,Storage:-25~+70℃ |
Humidity | ≤93%RH,In the place without dew and corrosive gas | |
Altitude | ≤2500m |
2.1、Test Report of SICEM
No. | Test Item | Allowed value | Actual value | Conclusion |
1 | Appearanceinspection | Visual control | Meet the demand | |
2 | Insulation resistance | ≥5MΩ | Meet the demand | |
3 | Voltage test | Voltage 2KV | Meet the demand | |
4 | Response time | 4s | 1.5s | Meet the demand |
5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
8 | Test of overshoot | ±20 | 0 | Meet the demand |
9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |
2.2、Advanced Test Equipment Imported
Test is more accurate, with highest precision and smallest error
2.1、Test Report of SICEM
No. | Test Item | Allowed value | Actual value | Conclusion |
1 | Appearanceinspection | Visual control | Meet the demand | |
2 | Insulation resistance | ≥5MΩ | Meet the demand | |
3 | Voltage test | Voltage 2KV | Meet the demand | |
4 | Response time | 4s | 1.5s | Meet the demand |
5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
8 | Test of overshoot | ±20 | 0 | Meet the demand |
9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |
2.2、Advanced Test Equipment Imported
Test is more accurate, with highest precision and smallest error