Quantity: | |
---|---|
KDSI Also can do OEM
Model | | BP-80 | BP-60 | BP-670 | BP-45 | ||
Front frame | mm | 80*80 | 60*60 | 60*70 | 50*50 | ||
Panel cutout | mm | 64 | 52 | 53 | 45.5 | ||
AC current | |||||||
Ranges | mA | 100mA 150mA 200mA 400mA 500mA 600mA 800mA | |||||
A | 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A | ||||||
Combined with an external C.T. | X/1A | 10/1A 15/1A 20/1A 30/1A 40/1A 50/1A 60/1A 75/1A 100/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 600/1A 800/1A 1000/1A 1200/1A 1500/1A 1600/1A 2000/1A 2500/1A 3000/1A More Ranges can be customized | |||||
X/5A | 10/5A 15/5A 20/5A 30/5A 40/5A 50/5A 60/5A 75/5A 100/5A 150/5A 200/5A 250/5A 300/5A 400/5A 500/5A 600/5A 800/5A 1000/5A 1200/5A 1500/5A 1600/5A 2000/5A 2500/5A 3000/5A More Ranges can be customized | ||||||
The common type is no overload,1.5 2.0 3.0 5.0 6.0 times overload can be customized | |||||||
AC voltage | |||||||
Ranges | V | 10V 25V 40V 50V 60V 100V 150V 250V 300V 450V 500V | |||||
KV | Combined with an external PT **/100V **/110V **/120V | ||||||
Model | BP-80 | BP-60 | BP-670 | BP-45 | |||
Front frame | mm | 80*80 | 60*60 | 60*70 | 50*50 | ||
Panel cutout | mm | 64 | 52 | 53 | 45.5 | ||
DC Current | |||||||
Ranges | uA | 50uA 100uA 150uA 250uA 800uA | |||||
mA | 4-20mA 1mA 10mA 500mA 800mA | ||||||
A | 1A 2A 3A 5A 10A 15A 20A 25A 30A 40A 50A | ||||||
For connecting to external shunt | 50mV 60mV 75mV | 10A 15A 20A 30A 40A 50A 60A 100A 150A 200A 250A 300A 400A 500A 600A 800A 1000A 1500A 2000A 2500A 3000A | |||||
DC voltage | |||||||
Ranges | V | 0.5V 1V 10V 25V 50V 100V 250V 500V 600V | |||||
Frequency Meters | |||||||
Measuring frequency ranging from 45-65Hz , Moving Coil movement.Voltage Fluctuation Allowance:+20% | |||||||
Frequency Meter | | Model | Measuring Rang | | Voltage | ||
| BP-80,BP-670 BP-45 | 45-55Hz 45-65Hz 55-65Hz | | 100V,220V,300V |
Model | | BP-80 | BP-60 | BP-670 | BP-45 | ||
Front frame | mm | 80*80 | 60*60 | 60*70 | 50*50 | ||
Panel cutout | mm | 64 | 52 | 53 | 45.5 | ||
AC current | |||||||
Ranges | mA | 100mA 150mA 200mA 400mA 500mA 600mA 800mA | |||||
A | 1A 5A 10A 15A 20A 25A 30A 40A 50A 60A | ||||||
Combined with an external C.T. | X/1A | 10/1A 15/1A 20/1A 30/1A 40/1A 50/1A 60/1A 75/1A 100/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 600/1A 800/1A 1000/1A 1200/1A 1500/1A 1600/1A 2000/1A 2500/1A 3000/1A More Ranges can be customized | |||||
X/5A | 10/5A 15/5A 20/5A 30/5A 40/5A 50/5A 60/5A 75/5A 100/5A 150/5A 200/5A 250/5A 300/5A 400/5A 500/5A 600/5A 800/5A 1000/5A 1200/5A 1500/5A 1600/5A 2000/5A 2500/5A 3000/5A More Ranges can be customized | ||||||
The common type is no overload,1.5 2.0 3.0 5.0 6.0 times overload can be customized | |||||||
AC voltage | |||||||
Ranges | V | 10V 25V 40V 50V 60V 100V 150V 250V 300V 450V 500V | |||||
KV | Combined with an external PT **/100V **/110V **/120V | ||||||
Model | BP-80 | BP-60 | BP-670 | BP-45 | |||
Front frame | mm | 80*80 | 60*60 | 60*70 | 50*50 | ||
Panel cutout | mm | 64 | 52 | 53 | 45.5 | ||
DC Current | |||||||
Ranges | uA | 50uA 100uA 150uA 250uA 800uA | |||||
mA | 4-20mA 1mA 10mA 500mA 800mA | ||||||
A | 1A 2A 3A 5A 10A 15A 20A 25A 30A 40A 50A | ||||||
For connecting to external shunt | 50mV 60mV 75mV | 10A 15A 20A 30A 40A 50A 60A 100A 150A 200A 250A 300A 400A 500A 600A 800A 1000A 1500A 2000A 2500A 3000A | |||||
DC voltage | |||||||
Ranges | V | 0.5V 1V 10V 25V 50V 100V 250V 500V 600V | |||||
Frequency Meters | |||||||
Measuring frequency ranging from 45-65Hz , Moving Coil movement.Voltage Fluctuation Allowance:+20% | |||||||
Frequency Meter | | Model | Measuring Rang | | Voltage | ||
| BP-80,BP-670 BP-45 | 45-55Hz 45-65Hz 55-65Hz | | 100V,220V,300V |
No. | Test Item | Allowed value | Actual value | Conclusion |
1 | Appearanceinspection | Visual control | Meet the demand | |
2 | Insulation resistance | ≥5MΩ | Meet the demand | |
3 | Voltage test | Voltage 2KV | Meet the demand | |
4 | Response time | 4s | 1.5s | Meet the demand |
5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
8 | Test of overshoot | ±20 | 0 | Meet the demand |
9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |
No. | Test Item | Allowed value | Actual value | Conclusion |
1 | Appearanceinspection | Visual control | Meet the demand | |
2 | Insulation resistance | ≥5MΩ | Meet the demand | |
3 | Voltage test | Voltage 2KV | Meet the demand | |
4 | Response time | 4s | 1.5s | Meet the demand |
5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
8 | Test of overshoot | ±20 | 0 | Meet the demand |
9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |