Quantity: | |
---|---|
BP-670
KDSI Also can do OEM
9030339000
No. | Test Item | Allowed value | Actual value | Conclusion |
1 | Appearanceinspection | Visual control | Meet the demand | |
2 | Insulation resistance | ≥5MΩ | Meet the demand | |
3 | Voltage test | Voltage 2KV | Meet the demand | |
4 | Response time | 4s | 1.5s | Meet the demand |
5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
8 | Test of overshoot | ±20 | 0 | Meet the demand |
9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |
No. | Test Item | Allowed value | Actual value | Conclusion |
1 | Appearanceinspection | Visual control | Meet the demand | |
2 | Insulation resistance | ≥5MΩ | Meet the demand | |
3 | Voltage test | Voltage 2KV | Meet the demand | |
4 | Response time | 4s | 1.5s | Meet the demand |
5 | Test of intrinsic error | ±1.5 | ±0.5 | Meet the demand |
6 | Test of tracking error | ±1.5 | ±0.6 | Meet the demand |
7 | Test of deviation from zero | ±0.75 | 0 | Meet the demand |
8 | Test of overshoot | ±20 | 0 | Meet the demand |
9 | Test of self-heating | ±1.5 | ±0.1 | Meet the demand |
10 | Test of variation due to distortion of a.c. measured quantity | ±1.5 | ±0.2 | Meet the demand |
11 | Test of variation due to position | ±0.75 | ±0.2 | Meet the demand |
12 | Test of variation due to frequency on a.c. measured quantity | ±1.5 | ±0.3 | Meet the demand |
13 | Test of variation due to a magnetic field of external origin | ±6 | ±0.2 | Meet the demand |
14 | Test of variation due to ambient temperature | ±1.5 | ±0.2 | Meet the demand |
15 | Test of variation due to ferromagnetic supports | ±1.5 | ±0.5 | Meet the demand |
16 | Short-time overload test | ±1.5 | ±0.5 | Meet the demand |
17 | Continuous overload test | ±1.5 | ±0.5 | Meet the demand |
18 | Vibration and shock test | ±1.5 | ±0.3 | Meet the demand |
19 | Temperature limits test | ±1.5 | ±0.2 | Meet the demand |
20 | Test of variation due to temperature | ±1.5 | ±0.2 | Meet the demand |